10
16
AP6
Arc striking board
PL06-A1
17
Air pressure regulating
filter
GFR-200-08
18
XS6
Ten cores socket
WS24K10Z
8
Protection instruction
Pressure protection
1.
When the gas pressure is lower than 0.2 MPa, the protection circuit woks and plasma will stop working;
2.
When cutting, if the pressure is lower than 0.15 MPa, the cutting arc will stop;
Note: the cutting pressure could only be adjusted when press the switch to “Air checking” on panel!
Over-heating protection
When environmental temperature is higher than 40
℃
or anything abnormal of cooling fan, working on rated
cutting current, if the plasma is over-heating, the over-heating protection circuit start to work and cutting stop.
Voltage Input fault protection
Any phase default or 20% higher or lower than standard voltage, the protection circuit works, and plasma stop
working.
9
Maintenance
1.The machine should not be used or store in the sun;
2.The machine should not be used or store in the wet;
3.The air hole should not be covered when using;
4.The cover should be opened at least once a year to clear the inner impurities and sundries;
5.Regularly check all the insulation of cables, anything br oken, it should be repaired soon;
6.Regularly check all the connections of machine, if anything loosen, it should be tighten soon;
7.Regularly clear the water and dirties in pressure regulating filter.
Note: when repair or maintenance, let a professional electrician remove the power line in distribution box,
then open the cover.
10
Trouble shooting and repairing
There is high voltage inside the machine, only professional electrician could repair the machine;
If anything wrong, please firstly check:
1
、
If the distribute voltage is normal and stable;
2
、
If the input fault indicator on panel light on, then check the power switch of distributor, fuse and power line, if
anything broken, the plasma stops;