Figure 5-17
Command
5.2.7 Commissioning Video Effects
Precautions
l
Before commissioning video effects, ensure the following:
–
The video captured by each lens of the tri-lens camera is displayed properly on the HD
displays.
–
The telepresence codecs' input and output parameters, especially the camera type and
the control serial port, have been set correctly.
–
The HD display parameters, such as the picture size and color, have been set correctly.
–
The video resolution, cable mode, and zoom value of the camera have been set correctly.
–
The natural light is kept out by the curtains. The lights in the conference room have
been turned on and the color temperature of the light sources in the room is the same.
l
When configuring camera settings from the web interface, ensure that you receive a
response before you proceed to set the next parameter (the interval between your operations
must be 1–2 seconds). Failure to do so may result in process blocks.
l
The camera automatically saves the settings each time after you set a parameter. After you
complete the settings for all parameters, wait 10 seconds before closing the camera
commissioning page or powering the camera off, to help ensure that the settings are
successfully saved.
Procedure
Log in to the telepresence host's web interface with the superadmin account. Right-click the
Tri-Lens Camera
button, and choose
Settings
to display the
Tri-Lens Camera Settings
page,
as shown in
and
.
HUAWEI TP3106&TP3118&TP3118S
Commissioning Guide
5 Video Device Configuration
Issue 01 (2015-02-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
122