Acceptance Manual
Tecal RH2485 V2 Server
Part II Operation Guide
17
Diagram
Preset Conditions
The server is powered on, and the hard disks are detected.
Test Procedures
1.
Press
Ctrl+H
in the POST phase. The window for configuring the LSI SAS2208
is displayed.
2.
Select four hard disks, divide them into two groups, and configure RAID 1
properties for both groups. For details, see case T05-02. For the second group,
select
Add Configuration
for
MegaRAID BIOS Config Utility Configuration
.
3.
Click
Home
. Click a hard disk in
Unconfigured Drives
on the right. In the
window for configuring the hard disk, select
Make Global HSP
and click
Go
to
set the hard disk to a global hot spare disk.
4.
Remove one RAID 1 member disk. Check whether the global hot spare disk
takes the removed disk's place and its state becomes
Rebuild
.
Expected Result
The global hot spare disk takes the removed disk's place and its state changes from
HotSpare
to
Rebuild
.
Test Description
T05-07 Setting and Verifying a Dedicated Hot Spare Disk by Using the Hard
Disk Controller LSI SAS2208
T05-0701 Setting and Verifying a Dedicated Hot Spare Disk by Using the Hard Disk
Controller LSI SAS2208
Objective
To verify that you can set a dedicated hot spare disk by using the LSI SAS2208
Test Networking
Diagram
None
Preset Conditions
The server is powered on, and the hard disks are detected.
Test Procedures
1.
Press
Ctrl+H
in the POST phase. The window for configuring the LSI SAS2208
is displayed.
2.
Select four hard disks, divide them into two groups, and configure RAID 1
properties for both groups. For details, see case T05-02. For the second group,
select
Add Configuration
for
MegaRAID BIOS Config Utility Configuration
.
3.
Click
Home
. Click a hard disk in
Unconfigured Drives
on the right. In the
window for configuring the hard disk, select
Drive Group0
and
Make Global
HSP
and click
Go
to set the hard disk to a dedicated hot spare disk for
Drive
Group0
.
4.
Click
Home
. Click a hard disk in
Unconfigured Drives
on the right. In the
window for configuring the hard disk, select
Drive Group1
and
Make Global
HSP
and click
Go
to set the hard disk to a dedicated hot spare disk for
Drive
Group1
.
5.
Remove one member disk for
Drive Group0
and
Drive Group1
. Check
whether the two dedicated hot spare disks take the removed disks' place and
their states become
Rebuild
.
Expected Result
The dedicated hot spare disk takes the removed disk's place and its state changes
from
HotSpare
to
Rebuild
.
Test Description