Table 2-10 Description of SAS/SATA drive indicators
Drive Activity
Indicator (Green
Indicator)
Drive Fault
Indicator (Yellow
Indicator)
Description
Steady on
Off
The drive is in position.
Blinking at 4 Hz
Off
Data is being read or written normally,
or data on the primary drive is being
rebuilt.
Steady on
Blinking at 1 Hz
The drive is being located by the RAID
controller card.
Blinking at 1 Hz
Blinking at 1 Hz
The data on the secondary drive is
being rebuilt.
Off
Steady on
A member drive in the RAID array is
removed.
Steady on
Steady on
A member drive in the RAID array is
faulty.
2.6.3 NVMe SSD Indicators
shows the NVMe SSD indicators.
Figure 2-20 NVMe SSD indicators
Table 2-11 NVMe SSD indicators
Drive Activity
Indicator
(Green
Indicator)
Drive Fault
Indicator
(Yellow
Indicator)
State Description
Off
Off
The NVMe SSD cannot be detected.
Steady green
Off
The NVMe SSD is detected and working
properly.
Blinking green
(2 Hz)
Off
Data is being read from or written to the
NVMe SSD.
Off
Blinking yellow
(2 Hz)
The NVMe SSD is being located or hot-
swapped.
Off
Blinking yellow
at 0.5 Hz
The NVMe SSD completes the hot removal
process and is removable.
TaiShan 200 Server
User Guide (Model 2280)
2 Components
Issue 04 (2020-01-16)
Copyright © Huawei Technologies Co., Ltd.
23