-------------- Mother Board INFO ---------------
Mainboard BoardID: 0x00b9
Mainboard PCB: .A
--------------- Riser Card INFO ----------------
Riser1 BoardName: BC11PRUCRiser1
BoardID: 0x0090
Riser1 PCB: .A
Riser2 BoardName: BC82PRNE
Riser2 BoardID: 0x0032
Riser2 PCB: .A
------------------- HDD Backplane INFO -------------------
Disk BP1 BoardName: BC11THBQ
Disk BP1 BoardID: 0x0073
Disk BP1 PCB: .A
Disk BP1 CPLD Version:(U3)1.10
-------------------- IO Board INFO -------------------
IOBoard5 ProductName: BC82IOBA
IOBoard5 BoardID: 0x0069
IOBoard5 PCB: .A
IOBoard5 CPLD Version: (U12)0.01
▪
CPLD Version: complex programmable logical device (CPLD) version
of the server
▪
BIOS Version: BIOS version of the server
▪
Active iBMC Version: active iBMC version of the server
▪
Backup iBMC Version: backup iBMC version of the server
e. Query the health status of the server.
iBMC:/->ipmcget -d health
System in health state
▪
If "System in health state" is displayed, no further action is required.
▪
If alarm information is displayed, go to the next step.
f.
Query any generated alarms.
iBMC / # ipmcget -d healthevents
Event Num | Event Time | Alarm Level | Event Code | Event Description
1 | 2019-02-10 00:52:23 | Minor | 0x12000021 | get description failed.
2 | 2019-02-10 01:37:42 | Minor | 0x12000013 | Failed to obtain data of the air inlet
temperature.
3 | 2019-02-10 00:52:23 | Minor | 0x12000019 | Right mounting ear is not present.
4 | 2019-02-10 00:52:19 | Major | 0x28000001 | The SAS or PCIe cable to front disk
backplane is incorrectly connected.
g. Clear alarms. For details, see the
TaiShan Rack Server iBMC Alarm
.
----End
5.11.6 Changing Initial Passwords
Change the following initial user passwords:
●
Initial password of the default iBMC user
●
Initial password for the iBMC U-boot
TaiShan 200 Server (Model 2280)
User Guide
5 Installation and Configuration
Issue 09 (2021-01-12)
Copyright © Huawei Technologies Co., Ltd.
74