Figure 5-77 Installing a FlexIO card
Step 8 Tighten the screw using the Phillips screwdriver to secure the FlexIO card. See (2)
in
A tool is required for this operation.
Step 9 Install the server. For details, see
5.4.3 Installing the Server on Guide Rails
Step 10 Connect network cables, or optical modules and optical cables to the FlexIO card.
Step 11 Connect the power cables. For details, see
Step 12 Power on the server. For details, see
.
Step 13 Log in to the iBMC WebUI, and check whether the new component is normal. For
TaiShan Rack Server iBMC User Guide
----End