Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
rrpp domain
domain-id
The RRPP domain view is displayed.
Step 3
Run:
ring
ring-id
node-mode
{
master
|
transit
}
primary-port
interface-type
interface-
number
secondary-port
interface-type
interface-number
level
level-value
An RRPP ring is created.
RRPP rings can be configured only on Ethernet interfaces, GE interfaces, and Eth-Trunk
interfaces.
The level 0 indicates the major ring, and the level 1 indicates the subring.
A domain can contain only one major ring. Before creating a subring, you must create the major
ring.
The master node on a subring cannot function as an edge node or an assistant edge node.
An S3700EI supports 16 rings.
Step 4
Run:
ring
ring-id
node-mode
{
edge
|
assistant-edge
}
common-port
interface-type
interface-number
edge-port
interface-type
interface-number
The edge node and assistant edge node of a subring are configured.
The common port of the edge node and assistant edge node must be on the major ring.
The system automatically sets the level of the ring where the edge node and assistant edge node
reside to 1.
----End
3.4.8 Enabling the RRPP Ring
The protocol packets of sub-rings are transmitted on the major ring as data packets; the protocol
packets of the major ring are transmitted on only the major ring. An RRPP ring can take effect
only when it is enabled.
Context
NOTE
The RRPP ring can be activated only when both the RRPP ring and RRPP protocol are enabled.
Do as follows on all switches in the RRPP domain:
Procedure
Step 1
Run:
Quidway S3700 Series Ethernet Switches
Configuration Guide - Reliability
3 RRPP Configuration
Issue 01 (2011-10-26)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
68