No.
Data
1
Interface to be associated and number of the interface
2
Names of the MD and MA
4.15.2 Configuring Association Between Ethernet CFM and
Ethernet CFM
Context
Do as follows on the devices where association between Ethernet CFM and Ethernet CFM needs
to be configured.
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
oam-mgr
The OAM management view is displayed.
Step 3
(Optional) Run:
oam-bind ingress cfm md
md-name1
ma
ma-name1
egress
cfm
md
md-name2
ma
ma-name2
Unidirectional fault transmission is enabled between Ethernet CFM modules at the two ends of
the link.
Step 4
(Optional) Run:
oam-bind cfm md
md-name1
ma
ma-name1
cfm
md
md-name2
ma
ma-name2
Bidirectional fault transmission is enabled between Ethernet CFM modules at the two ends of
the link.
Steps 3 to 4 are optional and can be selected as required.
NOTE
After bidirectional transmission of fault messages is configured, the system displays two configuration
records of unidirectional fault message transmission, whose directions are mutually reverse.
----End
4.15.3 Checking the Configuration
Prerequisite
The configurations of association between Ethernet CFM and Ethernet CFM are complete.
Quidway S3700 Series Ethernet Switches
Configuration Guide - Reliability
4 Ethernet OAM Configuration
Issue 01 (2011-10-26)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
207