l
The interface has been added to a Monitor Link group.
l
The interface has been added to another Smart Link group.
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
interface
interface-type
interface-number
The system view is displayed.
Step 3
Run:
stp
disable
STP is disabled on the interface.
Step 4
Run:
quit
Return to the interface view.
Step 5
Run:
smart-link group
group-id
The Smart Link group view is displayed.
Step 6
Run:
port
interface-type
interface-number
master
An interface is added to the Smart Link group and is specified as the master interface.
Step 7
Run:
port
interface-type
interface-number
slave
Another interface is added to the Smart Link group and is specified as the slave interface.
A Smart Link group consists of a master interface and a slave interface. By default, a Smart Link
group does not have interfaces.
----End
2.2.4 Enabling the Sending of Flush Packets
Context
When the active and standby links of the Smart Link group switch, the existing forwarding
entries no longer apply to the new topology. All the MAC address entries and ARP entries on
the network need to be updated. Then the Smart Link group sends Flush packets to ask other
devices to update the MAC address table and ARP entries.
Because manufacturers define the format of Flush packets differently, the Flush packets
described here are used only for the intercommunication between Huawei S-series switches. In
addition, the function of receiving Flush packets must be enabled on the remote switch.
Quidway S3700 Series Ethernet Switches
Configuration Guide - Reliability
2 Smart Link and Monitor Link Configuration