Step 7
Enable Smart Link on Switch A.
[SwitchA-smlk-group1]
smart-link enable
[SwitchA-smlk-group1]
quit
Step 8
Enable the receiving of Flush packets.
# Configure Switch B.
<SwitchB>
system-view
[SwitchB]
interface ethernet 0/0/1
[SwitchB-Ethernet0/0/1]
smart-link flush receive control-vlan 10 password simple
123
[SwitchB-Ethernet0/0/1]
quit
# Configure Switch C.
<SwitchC>
system-view
[SwitchC]
interface ethernet 0/0/1
[SwitchC-Ethernet0/0/1]
smart-link flush receive control-vlan 10 password simple
123
[SwitchC-Ethernet0/0/1]
quit
Step 9
Verify the configuration.
# Run the
display smart-link group
command to view information about the Smart Link group
on Switch A. If the following information is displayed, it indicates that the configuration is
successful.
l
The Smart Link function is enabled.
l
The control VLAN ID is 10.
l
Eth 0/0/1 is the master interface and is in Active state, and Eth 0/0/2 is the slave interface
and is in Inactive state. The load balancing function is configured.
[SwitchA]
display smart-link group 1
Smart Link group 1 information :
Smart Link group was enabled
Wtr-time is: 30 sec.
Load-Balance Instance: 10
There is no protected-vlan reference-instance
DeviceID: 0025-9e80-2494 Control-vlan ID:
10
Member Role State Flush Count Last-Flush-Time
----------------------------------------------------------------------
Ethernet0/0/1 Master
Active
1 0000/00/00 00:00:00 UTC+00
:00
Ethernet0/0/2 Slave
Inactive
0 0000/00/00 00:00:00 UTC+00
:00
# Run the
shutdown
command to shut down Eth 0/0/1, and you can find that Eth 0/0/1 is in
Inactive state and Eth 0/0/2 is in Active state.
[SwitchA]
interface ethernet 0/0/1
[SwitchA-Ethernet0/0/1]
shutdown
[SwitchA-Ethernet0/0/1]
display smart-link group 1
Smart Link group 1 information :
Smart Link group was enabled
Wtr-time is: 30 sec.
Load-Balance Instance: 10
There is no protected-vlan reference-instance
DeviceID: 0025-9e80-2494 Control-vlan ID:
10
Member Role State Flush Count Last-Flush-Time
----------------------------------------------------------------------
Ethernet0/0/1 Master
Inactive
1 0000/00/00 00:00:00 UTC+00
:00
Quidway S3700 Series Ethernet Switches
Configuration Guide - Reliability
2 Smart Link and Monitor Link Configuration
Issue 01 (2011-10-26)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
39