Procedure Operation
Nixie Tube Display
4
Press the left button to switch
between the high-, middle-, and
low-order nixie tubes. Press the
right button to adjust the value.
Adjusted group number
(middle- or low-order
nixie tube blinking)
5
Hold down the left or right button
to save the settings.
Group number (static).
Then, the voltage
display screen is
displayed.
2.5 Module Ports
Figure 2-4 DC output and signal ports
Table 2-9 Output port definition
Pin
Item
Function
1, 2
1000 V DC–
Negative output (pins 1 and 2
must be connected in parallel)
3, 4
1000 V DC+
Positive output (pins 3 and 4
must be connected in parallel)
5
CANBH
CAN high-level signal
6
CANBL
CAN low-level signal
7
CANBH
CAN high-level signal
8
CANBL
CAN low-level signal
9
CAN_GND
Signal ground
10
LINK_CHECK_OK
Insertion and removal control
11
URGENT_T
Emergency s
R100020G1 Charging Module
User Manual
2 Overview
Issue 05 (2021-11-16) Copyright © Huawei Digital Power Technologies Co., Ltd.
16