Planning device installation positions
Removing filler panels from device installation positions
2 Installing Devices
2b
2a
Recommended installation positions
Total required cabinet space = 2 U + 2 U x (Number of 2 U disk enclosures)
If Dorado NAS units are used, their space must also be counted, which is 2 U x (Number of Dorado NAS units).
For example, if the OceanStor Dorado5000 V3 Enhanced Edition (SAS) is equipped with four 2 U disk enclosures,
the space required by a cabinet can be calculated as follows:
10 U = 2 U + 2 U x 4
Note: The height of the storage system is measured by the unit of U. 1 U equals 44.45 mm (1.75 inches).
Tips
5
Install the controller
enclosure in the middle of
a cabinet between 19 U
and 20 U.
Controller enclosure (2 U)
Disk enclosure (2 U)
Disk enclosure (2 U)
Disk enclosure (2 U)
Disk enclosure (2 U)
Install devices from the
bottom up and from heavy
to light (The total power of
all the devices cannot
exceed the total power of
the cabinet).