N2000H V3 Appliance
User Guide
1 Product Overview
Issue 04 (2018-11-06)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
27
Item
Specifications
Dimensions (H x
W x D)
175 mm (4U) x 447 mm x 748 mm (6.89 in. x 17.60 in. x 29.45 in.)
Installation space
The Appliance fits into a universal rack that complies with the IEC
297 standard.
Rack width: 19 inches
Rack depth: > 1000 mm (39.37 in.)
Guide rail installation requirements are as follows:
L-shaped guide rails: apply only to Huawei racks.
Adjustable guide rails: apply to a rack where the distance between
the front and rear mounting bars is 543.5 mm to 848.5 mm.
Holding rails: apply to a rack where the distance between the front
and rear mounting bars is 610 mm to 914 mm.
PSU power rating
The PSUs support the following power ratings:
750 W
Weight in full
configuration
With 36 hard disks: 57 kg (125.69 lb)
With 24 hard disks: 48 kg (105.84 lb)
Packaging materials: 15 kg (33.08 lb)
Rated input
voltage
AC PSUs: 100 V to 240 V AC
DC PSUs: –48 V to –60 V DC
240 V HV DC PSUs: 192 V to 288 V DC
380 V HV DC PSUs: 260 V to 400 V DC
NOTE
The recommended current specification for the external power circuit breaker
connected to the Appliance is 32 A.
Temperature
Operating temperature: 5°C to 40°C (41°F to 104°F)
Storage temperature: –40°C to +65°C (–40°F to +149°F)
Temperature change rate: < 20°C/h (36°F/h)
NOTE
The N2000H V3 supports the maximum operating temperature of 35°C
(95°F) when it is equipped with rear hard disks.
The operating performance of hard disks may deteriorate when a single fan
module fails.
The N2000H V3 supports the maximum operating temperature of 35°C
(95°F) when it is equipped with Huawei PCIe SSDs.
The N2000H V3 supports the maximum operating temperature of 35°C
(95°F) when it is equipped with 135 W CPUs.
Altitude
≤ 3000 m (9842.40 ft)
When the N2000H V3 is used at an altitude of higher than 900 m
(2952.72 ft), the highest operating temperature decreases by 1°C
(1.8°F) as the altitude increases by 300 m (984.24 ft).
Humidity
Operating humidity: 8% RH to 90% RH (non-condensing)
Storage humidity: 5% RH to 95% RH (non-condensing)