N2000H V3 Appliance
User Guide
5 System Security Policy
Issue 04 (2018-11-06)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies
Co., Ltd.
122
Always install with elevated privileges: Disabled
5.1.2 Auditing and Account policies
1)
Account Lockout Policy
Account lockout duration: 15 minutes
Account lockout threshold: 10 invalid logon attempts
Reset account lockout counter after: 15 minutes
2)
Account Policy
Enforce password history: 24 passwords remembered
Maximum password age: 60 day(s).
Minimum password age: 1 day(s).
Minimum password length: 14 character(s).
Password complexity: Enabled
Store passwords using reversible encryption: Disabled
3)
Detailed Security Auditing
Account Logon
Credential Validation: Success & Failure
Account Management
Computer Account Management: Success & Failure
Distribution Group Management: Success & Failure
Other Account Management Events: Success & Failure
Security Group Management: Success & Failure
User Account Management: Success & Failure
Detailed Tracking
Process Creation: Success
DS Access
Directory Service Access: Success & Failure
Directory Service Changes: Success & Failure
Logon-Logoff
Account Lockout: Success
Logoff: Success
Logon: Success & Failure
Other Logon/Logoff Events: Success & Failure
Special Logon: Success