HUAWEI MU736 HSPA+ M.2 Module
Hardware Guide
RF Specifications
Issue 05 (2014-01-14)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
44
4.3 Conducted RF Measurement
4.3.1
Test Environment
Test instrument
R&S CMU200, Agilent E5515C, GSS6700
Power supply
Keithley 2303, Agilent 66319
RF cable for testing
Rosenberger Precision Microwave Cable
Murata coaxial cable
MXHP32HP1000
The compensation for different frequency bands relates to the cable and the test
environment.
The instrument compensation needs to be set according to the actual cable conditions.
4.3.2
Test Standards
Huawei modules meet 3GPP TS 51.010-1 and 3GPP TS 34.121-1 test standards.
Each module passes strict tests at the factory and thus the quality of the modules is
guaranteed.
4.4 Conducted Rx Sensitivity and Tx Power
4.4.1
Conducted Receive Sensitivity
The conducted receive sensitivity is a key parameter that indicates the receiver
performance of MU736.
The
3GPP Protocol Claim
column in Table 4-2 lists the required minimum values,
and the
Test Value
column lists the tested values of MU736.
Table 4-2
MU736 conducted Rx sensitivity (Unit: dBm)
Item
3GPP Protocol
Claim (dBm)
MU736 Test Value (dBm)
Min.
Typ.
Max.
GSM850
GMSK (CS1, BLER <
10%)
<
–102
-
-
–108
8PSK (MCS5, BLER <
10%)
<
–98
-
-
–101
GSM900
GMSK (CS1, BLER <
10%)
<
–102
-
-
–108
8PSK (MCS5, BLER <
10%)
<
–98
-
-
–101