HUAWEI MU736 HSPA+ M.2 Module
Hardware Guide
Electrical and Reliability Features
Issue 05 (2014-01-14)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
55
Figure 5-1
Power Supply During Burst Emission
The minimum value of the power supply must be guaranteed during the burst (with 2. 5 A Peak
in GPRS or EGPRS mode).
Table 5-7
Requirements for input current of the MU736 module
Power
Peak (Maximum)
Normal (Maximum)
3.3 V
2500 mA
1100 mA
5.5.2
Power Consumption
The power consumption of MU736 in different scenarios are respectively listed in
Table 5-8 to Table 5-12 .
The power consumption listed in this section is tested when the power supply of
MU736 module is normal voltage (3.3 V), and all of test values are measured at room
temperature.
Table 5-8
Averaged power off DC power consumption of MU736
Description
Test Value (uA)
Notes/Configuration
Typical
Power off
50
Normal voltage (3.3 V) is ON and
Power_On_Off pin is pulled low.