3.24 ^CLSNM–Manipulate Special Call Numbers
3.24.1
Command Syntax
Command
Possible response(s)
^CLSNM=<password>[,
<index>[,<number>]]
In case of write or delete:
<CR><LF>OK<CR><LF>
In case of read:
[<CR><LF>^CLSNM:<index>,<number>[<CR><LF>^
CLSNM:<index>,<number>[...]]<CR><LF>]<CR><LF>
OK<CR><LF>
In case of MT-related error:
<CR><LF>+CME ERROR:<err><CR><LF>
^CLSNM=?
^CLSNM: (list of supported<index>s)
<CR><LF><CR><LF>OK<CR><LF>
3.24.2
Description
<password>: field can
‟t be ignored when write, read, modify and delete.
Correct password should be submitted first (quotation marks must be added),
operations are not allowed if wrong password was submitted. If there are three
parameters, both <index> and <number> fields are not empty (<number> must added
quotation marks), this command is used to write special numbers into NV specified by
<index>.
If there are three parameters, the <number> is empty quotation marks, delete the
special number specified by <index>.
If the <password> field and <index> field are not empty, and the field following the
comma is blank, ERROR is returned.
If there are two parameters, <password> field and <index> field, read the special
number specified by <index>; If there is only <password> field, read all the
special numbers.
The TEST command returns the position range of the currently selected NV memory.
3.24.3
Defined Values
<password>: string type, set by ^CLSPWM command , the length is between 8 and 32.
Legal characters include 0
–9 and English characters, a–z or A–Z, and there is case
sensitive.
<index>: integer value. It indicates the position in NV memory. The value of index is
between 0 and 19.