HUAWEI MU509 HSDPA LGA Module
AT Command Interface Specification
Call Control Commands
Issue 04 (2013-01-28)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
135
80: 28800 bps (V.110 or X.31 flag stuffing)
81: 38400 bps (V.110 or X.31 flag stuffing)
83: 56000 bps (V.110 or X.31 flag stuffing)
84: 64000 bps (X.31 flag stuffing; this setting can be used in conjunction with
asynchronous non-transparent UDI service in order to get FTM)
116: 64000 bps (bit transparent)
134: 64000 bps (multimedia)
<name>:
0: Data circuit asynchronous (UDI or 3.1 kHz modem) (default value)
1: Data circuit synchronous (UDI or 3.1 kHz modem) (reserved, not supported)
4: Data circuit asynchronous (RDI) (reserved, not supported)
<ce>:
0: Transparent
1: Non-transparent (default value)
Note:
AT+CBST is the same as AT+CBST=0,0,1.
9.9 +CLCC–List Current Calls
9.9.1
Command Syntax
Command
Possible response(s)
+CLCC
[<CR><LF>+CLCC: <id1>,<dir>,<stat>,<mode>,<mpty>,
<number>,<type><CR><LF>
[<CR><LF>+CLCC: <id2>,<dir>,<stat>,<mode>,<mpty>,
<number>,<type><CR><LF>[
…]]]
<CR><LF>OK<CR><LF>
In case of MS-related error:
<CR><LF>ERROR<CR><LF>
<CR><LF>+CME ERROR: <err><CR><LF>
+CLCC=?
<CR><LF>OK<CR><LF>