HUAWEI MU509 HSDPA LGA Module
AT Command Interface Specification
Phonebook Commands
Issue 04 (2013-01-28)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
165
12
Phonebook Commands
12.1 +CPBS–Select Phonebook Memory
12.1.1
Command Syntax
Command
Possible response(s)
+CPBS=<storage>
[,<reserved>]
<CR><LF>OK<CR><LF>
In case of MS-related error:
<CR><LF>+CME ERROR: <err><CR><LF>
+CPBS?
<CR><LF>+CPBS: <storage>,<used>,<total><CR><LF>
<CR><LF>OK<CR><LF>
In case of MS-related error:
<CR><LF>+CME ERROR: <err><CR><LF>
+CPBS=?
<CR><LF>+CPBS: (list of supported <storage>s)
<CR><LF>
<CR><LF>OK<CR><LF>
12.1.2
Description
The SET command is used to select a phonebook memory. The initial value after
restarting the MS is “SM”. Other phonebook-related commands will be operated by
using the memory selected via this command.
The READ command returns the currently selected phonebook memory. Optionally,
the number of entries in use and the maximum number of entries should also be
returned.
The TEST command returns the supported phonebook memory types.
12.1.3
Defined Values
<storage>: phonebook me
mory type. Currently, only “SM” and “ON” are supported.