Item
Specification
Availability
0.999998327
Slot quantity
22
Redundant MPUs
1:1
Redundant Switch fabrics
3+1
Redundant fans
2 partitions
2 assemblies/partition, each partition in support for
proper fan operation in case of a single fan failure
for a short period at 40°C (104°F)
Redundant power supply
4+4
Forwarding performance
5760 Mpps (BSUF-240)
Switching capacity
12.58 Tbps (BSUF-240)
Operating temperature
Long-term: 0°C to 45°C (32°F to 113°F)
Short-term: –5°C to +55°C (23°F to131°F)
Remark: Restriction on the temperature variation
rate: 30°C/hour (86°F/h)
Storage temperature
–40°C to +70°C (–40°F to +158°F)
Relative operating humidity
Long term: 5% to 85% RH, non-condensing
Short term: 5% to 95% RH, non-condensing
Relative storage humidity
5% to 95% RH, non-condensing
Long-term operating altitude
<= 4000 m (13123.2 ft.) (For the altitude in the range
of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the
operating temperature of the NEU100 must decrease
by 1°C [33.8°F] for every 220 m [721.78 ft.].)
Storage altitude
Less than 5000 m (16404 ft.)
1.7.5 ME60-X16A
Overview
Table 1-10
Device attributes
Product Type Description
BOM
Model
Earliest
Software
Version
Содержание ME60 Series
Страница 1: ...ME60 V800R009C10SPC200 Hardware Description Issue 01 Date 2018 05 07 ...
Страница 47: ...ME60 Hardware Description 1 Hardware Description Issue 01 2018 05 07 38 Appearance Figure 1 11 Appearance ...
Страница 52: ...ME60 Hardware Description 1 Hardware Description Issue 01 2018 05 07 43 Appearance Figure 1 15 Appearance ...
Страница 58: ...ME60 Hardware Description 1 Hardware Description Issue 01 2018 05 07 49 Appearance Figure 1 19 Appearance ...
Страница 64: ...ME60 Hardware Description 1 Hardware Description Issue 01 2018 05 07 55 Appearance Figure 1 22 Appearance ...
Страница 155: ...ME60 Hardware Description 1 Hardware Description Issue 01 2018 05 07 146 Figure 1 86 Board ...