When the system is fully configured, temperatures reported by the temperature sensors on the
LPUs, SFUs, and MPUs serve as the basis for fan speed adjustment. Table 1-96 lists general
principles.
Table 1-96
Fan Speed Adjustment Principles
Ambient
Temperat
ure
Rotational
Speed
Noise and Dissipation Standards
-5°C -
+27°C
(23°F -
80.6°F)
Low speed (50%)
When fans rotate at a constantly low speed and the fans
meet heat dissipation requirements of a fully configured
system.
27°C -
40°C
(80.6°F -
104°F)
Linear variation
The fan speed is adjusted smoothly in linear mode,
without a sharp increase in noises.
Over 40°C
(104°F)
High speed
(100%)
Fans rotate at high speed to meet heat dissipation
requirements.
1.9.4.3 Fan Module
The fan modules, each containing one fan, are located side by side at the air exhaust vent. If a
single fan fails, the system can still work normally at an ambient temperature of 40°C (104°F)
for a short period of time.
Overview
Table 1-97
Fan attributes
Attribute
Description
Description
Fan Box
BOM
02120562
Model
CR5M000FBX60
Table 1-98
Mapping products and versions
Product
Earliest Software Version
X8
V800R008C10
X16
V800R008C10
Содержание ME60 Series
Страница 1: ...ME60 V800R009C10SPC200 Hardware Description Issue 01 Date 2018 05 07 ...
Страница 47: ...ME60 Hardware Description 1 Hardware Description Issue 01 2018 05 07 38 Appearance Figure 1 11 Appearance ...
Страница 52: ...ME60 Hardware Description 1 Hardware Description Issue 01 2018 05 07 43 Appearance Figure 1 15 Appearance ...
Страница 58: ...ME60 Hardware Description 1 Hardware Description Issue 01 2018 05 07 49 Appearance Figure 1 19 Appearance ...
Страница 64: ...ME60 Hardware Description 1 Hardware Description Issue 01 2018 05 07 55 Appearance Figure 1 22 Appearance ...
Страница 155: ...ME60 Hardware Description 1 Hardware Description Issue 01 2018 05 07 146 Figure 1 86 Board ...