No.
Cable
Type
Recommended
Specifications
Source
3
Ground cable
Single-core outdoor
copper cable
● 8 mm
2
Prepared
by the
customer
Table 5-2 Cables delivered with the battery
No.
Cable
Type
Source
a
DC input power cable (power
control module to battery
expansion module)
Common outdoor PV
cable in the industry
Delivered
with the
product
b
Signal cable (power control
module to battery expansion
module)
Outdoor shielded twisted
pair cable
Delivered
with the
product
c
Ground cable (between the
power control module and
battery expansion modules)
Single-core outdoor
copper cable
Delivered
with the
product
NO TE
● The minimum cable diameter must comply with local cable standards.
● The factors that affect cable selection include the rated current, cable type, routing
mode, ambient temperature, and maximum expected line loss.
5.2 Internal Electrical Connections of the Battery
NO TE
Internal cables are delivered with the battery. For details, see the
Packing List
in the packing
case.
5.2.1 Installing an Internal Ground Cable
Precautions
D ANGER
Ensure that the PE cable is securely connected. Otherwise, electric shocks may
occur.
LUNA2000-(5-30)-NHS0
User Manual
5 Electrical Connection
Issue 06 (2022-03-01)
Copyright © Huawei Technologies Co., Ltd.
43