kW power, the loads consume 4 kW power, and the grid supplies 1 kW power to
the loads.
Figure 3-9 time-of-use
(
set the discharge time
)
Fully Fed to Grid
●
This mode applies to the grid-tied scenario where PV energy is fully fed to the
grid.
●
This mode maximizes the PV energy for grid connection. When the generated
PV energy in the daytime is greater than the maximum output capability of
the inverter, the batteries are charged to store energy. When the PV energy is
less than the maximum output capability of the inverter, batteries discharge
to maximize the output energy of the inverter to the grid.
●
In this mode, Fully fed to grid is selected. For details, see
Example of fully fed to grid:
For example, when the PV modules generate 8 kW power, the SUN2000-5KTL
inverter connects to the grid with the maximum output power of 5.5 kW, and the
batteries charge 2.5 kW power. When the sunlight becomes weak, the PV modules
generate 3 kW power, the batteries charge 2.5 kW power, and the inverter
connects to the grid with the maximum output power of 5.5 kW.
LUNA2000-(5-30)-S0
User Manual
3 Application Scenarios and Settings
Issue 07 (2022-01-10)
Copyright © Huawei Technologies Co., Ltd.
34