Страница 1: ...eSpace EGW1500E Enterprise Gateway V100R001C06 Quick Start Issue 03 Date 2011 12 20 HUAWEI TECHNOLOGIES CO LTD ...

Страница 2: ... customer All or part of the products services and features described in this document may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this document is subject ...

Страница 3: ...ing Check 2 1 4 Customer Requirement Analysis and Network Planning 3 2 Hardware Installation 5 2 1 Preparing Installation Tools 5 2 2 Installing EGW1500E 5 2 3 Connecting Cables 6 2 4 Powering On the EGW1500E 7 3 Product Function Configuration 8 3 1 Logging In to the Web Management System 8 3 2 Configuring Internet Access 9 3 3 Configuring Voice Functions 12 4 FAQs 20 5 Qualification Card 22 6 Dec...

Страница 4: ...oid risk of electric shock and other potential risk z Use the power supply adapter provided with this product z Keep your hands dry when plugging in or out the device cable z When the device is not in use the power should be turned off and the mains power cable should be disconnected from the mains supply z Keep water and other liquids away from the device In the event of liquid coming into contac...

Страница 5: ... device in an environment without direct and strong sunlight Interven tion pro of Prevent the device from other RF devices within 50 meters Place the device at the center of the working area by considering the WLAN coverage range Install the antennas vertically to get the best WLAN performance AC power In the equipment room a stable AC power supply that meets the power requirements of the equipmen...

Страница 6: ...tain and the typical networking Collecting Customer Requirements You need to obtain customer requirements as listed in Table 1 3 before installing and configuring the device Table 1 3 Customer requirements Item Description Internet access Determine the access mode ADSL or WAN and whether the customer requires 3G network backup Number of POTS users Determine the number of POTS phones Number of SIP ...

Страница 7: ...eSpace EGW1500E Enterprise Gateway Quick Start 1 Planning and Preparation Issue 03 2011 12 20 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 4 Figure 1 1 Typical networking ...

Страница 8: ...500E on a horizontal surface place it on the surface Table 2 1 Installation tools Phillips screwdriver Claw hammer Hammer drill Level ruler 2 2 Installing EGW1500E Install an EGW1500E on a horizontal surface or on the wall Installing EGW1500E on a horizontal surface is easy You only need to place it on the surface and leave 10 cm space around for heat dissipation To install an EGW1500E on the wall...

Страница 9: ... 3 Connecting Cables This topic describes how to connect cables for the EGW1500E Select a cable connection mode based on the site requirements Figure 2 2 and Figure 2 3 show the cable connection modes Figure 2 2 ADSL access The ADSL splitter separates voice and data signals You can connect the splitter to ADSL and FXO ports of the EGW1500E or connect ADSL ports on user devices to the ADSL port of ...

Страница 10: ...z The EGW1500E provides four POTS interfaces PHONE1 to PHONE4 which can connect to common phones or fax machines To use more than four POTS interfaces connect the EGW1500E to an IAD 2 4 Powering On the EGW1500E After cables are connected press the power button to power on the EGW1500E View the power supply indicators and verify that the EGW1500E is working properly Before pressing the power button...

Страница 11: ...set parameters detect faults and upgrade devices Procedure Step 1 Set the mode in which IP addresses are obtained to Obtain an IP address automatically Step 2 Log in to the EGW1500E using Internet Explorer 6 0 or later The default URL is http 192 168 1 1 The default IP address of the EGW1500E login user name and password can be obtained from the label at the bottom of the EGW1500E Step 3 Enter the...

Страница 12: ...ns see the eSpace EGW1500E Enterprise Gateway Product Documentation Table 3 1 Internet access function Description Through ADSL Through the WAN port Select one out of the two NOTE z The EGW1500E connects to the IP network using an ADSL port a WAN port or a 3G data card The 3G data card is the backup of an ADSL or WAN port When the ADSL or WAN port is unavailable the EGW1500E can connect to the IP ...

Страница 13: ...configuration according to Figure 3 3 Table 3 2 Figure 3 5 Table 3 4 Figure 3 4 and Table 3 3 Figure 3 3 Setting ADSL parameters Table 3 2 ADSL parameters Parameter Description VPI Virtual path identifier VPI which is obtained from the network carrier VCI Virtual channel identifier VCI which is obtained from the network carrier PPPoE User Name User name to access the network which is obtained from...

Страница 14: ...E is used z PPPoE User Name user name to access the network which is obtained from the network carrier z PPPoE Password password to access the network which is obtained from the network carrier Static IP Indicates that the static IP address of the EGW1500E is used The setting must be the same as that on the Broadband Remote Access Server BRAS of the network carrier DHCP As a DHCP client the EGW150...

Страница 15: ...munication which prevents unauthorized listening and access The default password is the MAC address of the EGW1500E which can be viewed from the bottom label of the device End Verification To verify that the ADSL WAN connection is set up proceed as follows Step 1 Choose System Network The Network page is displayed Step 2 Check the value of Status If the value of Status is Connected the ADSL WAN co...

Страница 16: ... to the IMS network User Internal No External No Registr ation Group Register Type Sip Trunk ID Sip Trunk Name IMS Domai n User1 6001 00865718 7654321 User2 6002 00865718 7654322 User3 6003 00865718 7654323 0 Group 86571 8765432 1 865718 7654321 abc de f com abc def c om User Number Planning NGN Table 3 6 describes the number plan for the phones connected to the NGN network Obtain the external num...

Страница 17: ...3 Perform configurations according to the following tables Click to save the settings Table 3 8 Parameter description 1 Parameter Description Working Mode z Master active server The server that is added first is the active server z Slave standby server Recovery Whether to enable the failback function When the active server fails resources and services will be automatically switched to the standby ...

Страница 18: ...standby server NOTE If you set DNS Type to SRV you do not need to configure the slave SIP server z HOST One domain name corresponds to one IP address To perform switchover between the active and standby servers two SIP servers need to be configured Server Type SIP network type The value is provided by the network carrier Port Port number of the SIP server The value is provided by the network carri...

Страница 19: ...ion Authentication mode when a registration group registers with the IMS or NGN The value is provided by the network carrier Password The value is provided by the network carrier Sip Trunk ID The value is provided by the network carrier Sip Trunk Name The value is provided by the network carrier IMS Domain The value is provided by the network carrier Expiration Time Indicates the time when the SIP...

Страница 20: ... External number of the user which is used for outgoing and incoming calls It is provided by the carrier This parameter is valid after you set the Registration Group parameter The external number cannot conflict with any service prefixes emergency numbers outer office numbers or other intra office numbers NOTE Registration Group bound to External No must correspond to Sip Trunk ID If Sip Trunk ID ...

Страница 21: ... digit number which can be user defined It cannot conflict with any service prefixes emergency numbers outer office numbers or other intra office numbers User Name A string of 1 64 characters which can be user defined For example Jack Registration Group Registration group used when a POTS user registers with the IMS or NGN NOTE If the required registration group does not exist choose Voice Sip Ser...

Страница 22: ...es the call which reduces the connection duration Use the default settings To customize the settings see the eSpace EGW1500E Enterprise Gateway Product Documentation User State User status End Configuring an IP Phone Set the IP phone s IP address SIP user s internal number and IP address of the SIP server EGW1500 to register the IP phone with the EGW1500E For details see related IP phone manuals I...

Страница 23: ...tings in either of the following ways Press the RESET button on the EGW1500E with an acicular object for at least 6 seconds Choose Management Configuration Restore on the navigation bar click Restore Default and set relevant parameters on the displayed page 3 Q Why did I fail to log in to the web management system A Ensure that you have correctly entered the IP address of the EGW1500E user name an...

Страница 24: ...fore they do not interfere with each other This allows you to make a call and access the Internet simultaneously without degrading the call quality or lowering the Internet access rate 7 Q What can I do if I forget the WPA key A You can view the WPA key by logging in to the web management system of the EGW1500E Choose WLAN Security and click Click here to display next to WPA Key 8 Q Why wireless s...

Страница 25: ...eSpace EGW1500E Enterprise Gateway Quick Start 5 Qualification Card Issue 03 2011 12 20 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 22 5 Qualification Card ...

Страница 26: ...roducts Hazardous Substances Parts Pb Hg Cd Cr6 PBB PBDE Mechanical part Board circuit module Signal cable Cable connector Power adapter Auxiliary equipment Indicates that the concentration of the hazardous substance contained in all the homogeneous materials of this part is below the limit requirement of the SJ T 11363 2006 standard Indicates that the concentration of the hazardous substance cont...

Страница 27: ...m lead z The high temperature type solder used for the connector inside the transformer contains more than 85 lead z The luminescence glass of chip inductor contains lead z The high temperature type solder used for the transistor chip contains lead z The glass of resistance layer and protection layer is immune from lead z The pin and solder of the components such as the IC and power unit contain l...