User Manual
Airbridge cBTS3612 CDMA Base Station
System Description
1 System Overview
1-6
Current equalization hot backup, centralized management, and decentralized power
supply are enabled. It makes the power supply system safer and more reliable. It
provides automatic alarming through monitoring interface for the power fan, input
under-voltage, output over-voltage, overheat and protection against reverse
connection. This ensures the reliability of the power system. Remote power on/off
function enables unattended BTS operation and remote maintenance.
1.2.6 Multi-band supported
Now the cBTS3612 base station support the following band class specified in
TIA/EIA-97-D Recommended Minimum Performance Standards for cdma2000
Spread Spectrum Base Stations.
Band Class 0 (800 MHz Band ).
Band Class 1 (1900 MHz Band).
Band Class 5 (450 MHz Band ).
To support the different band classes, RF modules with different specifications
should be configured in cBTS3612 base station.
1.3 Technical Index
I. Structure and environment indices
Cabinet dimensions (Top set excluded)
1800mm x 800mm x 650mm (H x W x D)
Power supply
-48V DC (-40 - -60V DC)
Operational environment
Temperature: -5°C ~ 50°C
Relative humidity: 5% ~ 90%
Equipment room noise
70dBA (With intelligent fan control. The noise varies with the
ambient temperature)
&
Note:
In terms of environment adaptability, cBTS3612 conforms to the following specifications: IEC 60721-3
series, IEC 60068-2 and ETS 300 019-2 series. For details, please refer to Appendix C Environment
Performance.
Equipment room noise is In compliance with ETS 300 753 Noise Requirement for telecommunication
equipment and base station environment. When the inside temperature of cBTS3612 equipment room
is 50
â
C, the equipment noise is less than 70dBA, and when the temperature is 25
â
C, the equipment
noise is less than 60dBA.