User Manual
Airbridge cBTS3612 CDMA Base Station
System Description
Appendix C Environment Performance
C-2
3) Transportation environment
In compliance with IEC60721 -3-2 2K4/2B2/2C2/2S2/2M2 and IEC 300 019 -2-2 T2.3
"Public Transportation" level.
Precipitable particle
3
m
2
h
Floating particle
No requirement
mg/m
3
Gravel
100
mg/m
3
C.3 Illumination
1) Operation environment
In compliance with IEC60721-3-3 3K3/3Z2/3Z4/3B1/3C2/3S3/3M1 and ETS 300
019-2-3 T3.1 environment level. In normal operation, solar radiation should not
exceed 700W/m
2
, thermal radiation should not exceed 600W/m
2
, and illumination
should satisfy the requirement for working visibility and comfort.
2) Storage environment
In compliance with IEC60721-3-1 1K4/1Z2/1Z3/1B2/1C2/1S3/M2 and IEC 300
019-2-1 T1.2 "Weather Protection, No Temperature Control" level. In normal storage
place, the solar radiation should not exceed 1120W/m
2
, thermal radiation should not
exceed 600W/m
2
, and illumination should satisfy the requirement for working
visibility and comfort.
3) Transportation environment
In compliance with IEC60721 -3-2 2K4/2B2/2C2/2S2/2M2 and IEC 300 019 -2-2 T2.3
"Public Transportation" level. In normal transportation conditions, the solar radiation
should not exceed 1120W/m
2
, thermal radiation should not exceed 600W/m
2
, and
illumination should satisfy the requirement for working visibility and comfort.
C.4 Atmospheric Condition
1) Operation environment
In compliance with IEC60721-3-3 3K3/3Z2/3Z4/3B1/3C2/3S3/3M1 and ETS 300
019-2-3 T3.1 environment level:
Atmospheric pressure
70~106
kPa
Wind speed
5
m/s
SO
2
0.3~1.0
mg/m
3
H
2
S
0.1 ~0.5
mg/m
3
Cl
2
0.1 ~0.3
mg/m
3
HCl
0.1 ~0.5
mg/m
3
NO
x
0.5 ~1.0
mg/m
3
NH
3
1.0 ~3.0
mg/m
3
HF
0.01 ~0.03
mg/m
3
O
3
0.05 ~0.1
mg/m
3