WenZhou ZhengBang Electronic Equipment Co., Ltd
ZB4050LS Rev 1.1
34
Fig.5-4 Mark1 Calibration
Fig.5-5 Mark2 Calibration
2.After the Mark calibration, the reclaiming and visual correction (material with the calibration enabled by the feeder) are
automatically performed and placed until the production of this program is completed.
3.Pause
:
If you need to stop adjusting settings and continue production, please click "Pause".
After pausing the settings, click "Start" to continue production.
4.Stop
:
If you give up or interrupt the production no longer, please click "Stop"
Click "Start" after stopping will restart production from the beginning.
5-2-2 Single Step Production
Single-step execution is mainly for machine debugging, program calibration, troubleshooting, etc., and each step can be
clearly observed.
1. Click “Single Step” to recognize Mark1 and adjust the coordinate correction offset.
2. Click "single step" to recognize Mark2, adjust the coordinate correction offset
,
3. Step by step "single step", the system gradually withdraws material, visually corrects, and gradually installs until the
production is completed.
,
4. Click "Pause" and then click "Start" to switch to normal production automatic placement until the production is
completed.
5-2-3 Jump Production
If operator quit during production process and want to continue to work or skip some components, jump production can be adopted to
solve problem.