4.Click “Nozzle Correction-PCB Camera”, stamp 6 nozzles to the inkpad center from 4 different angles and then move them to the
paper to repeat the mark point.
Fig.3-3 Nozzle Calibration
Fig.3-4 Stick inkpad
Fig.3-5 Mark Point
5. Select the nozzle(need correct),click“Confirm”to edit
,
Click“Position”to position the camera to the mark point, adjust the
coordinate is aligned with the mark point center, click “Confirm” to complete the nozzle correction.
Fig. 3-6 Coordinate Correction
6.Refer to step 5 to complete the other nozzles calibration one by one.