WenZhou ZhengBang Electronic Equipment Co., Ltd
ZB4050LS Rev 1.1
13
Fig.3-12 Calibration Result
2
、
Refer to step 1 to complete other nozzle correction one by one.
3-3 System Setting
1. Language: Chinese ↔ English
Select the desired language, click “Confirm” to save the data, exit the software and then log in again to switch languages.
2. Mount Mode
Running type: The placement mode is completed one by one in the order of the components of the production file.
3. Throw Coordinate
The machine supports the position modification. First, place the throwing box on the work table behind the rail,then click “scraping
coordinate” to move the head to the top of the box to save the data(Subject to the watch nozzle above the box).
4. Throw Time
Delay time setting, subject to factory setting (50ms), advice: Don’t modify the data privately.
5. Automatic reset
If you active this function, when times of mounting reached target number, device will be reset automatically to ensure the accuracy of
the data. According to the number of setting required for production to save date.
6. Conveyor Delay
In order to match the speed of the transfer board, set the delay time of the stop board. When the PCB board reaches the position of the
baffle cylinder, the baffle cylinder is retracted after the delay time is counted to prevent the PCB board from overshooting and causing
the position to stop.
7. Conveyor Speed
Set the speed of loading and unloading of PCB
8. Conveyor Speed
Since the board detection sensor is not in the same vertical position as the damper cylinder, it is necessary to set the board delay time to
ensure that the PCB board can reach the damper cylinder position.
9. Open Lid(Cover Status)
Open cover and suspend: if the front and rear cover is opened during the operation of the device, the device will immediately switch to
the suspended state.
If the cover is opened during operation, the device will immediately switch to the low-speed operation mode.
10. Use of Guide Rail
SMT:Switch to the pick and place mode to meet the mounter's three-stage transfer plate mounting requirements.
Inspection conveyor:Switch to the conveyor mode and use the mounter as the convyor (select this mode when multiple devices online
backend devices are not mounted).
Содержание ZB4050LS
Страница 1: ...WenZhou ZhengBang Electronic Equipment Co Ltd ZB4050LS Rev 1 1 ...
Страница 45: ...42 ...