5.3
Space Heating, Space Cooling and Domestic Hot Water
Floor heating loops and fan coil units are used for space heating and fan coil units are used for space cooling. Domestic hot
water is supplied from the domestic hot water tank connected to the Mono unit. The unit switches to heating or cooling
mode according to the temperature detected by the room thermostat. In space cooling mode, the 2-way valve is closed to
prevent cold water entering the floor heating loops.
Figure 1-5.3: Space heating, space cooling and domestic hot water
Legend
1
Outdoor unit
10
Two-way valve (field supplied)
2
Plate heat exchanger
11
Distributor (field supplied)
3
Backup electric heater (customized)
12
Collector (field supplied)
4
Internal circulator pump
13
Domestic water tank (field supplied)
5
Stop valve (field supplied)
14
Heat exchanger coil
6
User interface
15
Immersion heater
7
Room thermostat (field supplied)
FHL 1...n
Floor heating loops (field supplied)
8
Motorized 3-way valve (field supplied)
FCU 1...n
Fan coil units (field supplied)
9
External circulator pump (field supplied)
Notes:
1.
The example is just for application illustration; please confirm the exact installation method according
to the installation manual.