7.11
HOLIDAY AWAY SETTING Menu
MENU > FOR SERVICEMAN > HOLIDAY AWAY SETTING
The
HOLIDAY AWAY SETTING
menu settings are used to set the outlet water
temperature to prevent water pipes freezing when away from home in cold
weather seasons. In
HOLIDAY AWAY SETTING
the following parameters should
be set.
T1S_H.A._H
sets the heat pump’s leaving water set temperature for space
heating mode when in holiday away mode.
T5S_H.M_DHW
sets the heat pump’s leaving water set temperature for DHW mode when in holiday away mode.
7.12
SERVICE CALL Menu
MENU > FOR SERVICEMAN > SERVICE CALL
In
SERVICE CALL
the following parameters can be set.
PHONE NO.
and
MOBILE NO.
can be used to set after-sales service contact
numbers. If set, these numbers are displayed to users in
MENU
>
SERVICE
INFORMATION
.
Use
▼
▲
to adjust the numerical values. The maximum length of the phone
numbers is 13 digits.
The black rectangle found between 0 and 9 when scrolling up and down using
▼
▲
is converted to a blank space when
the phone numbers are displayed to users in
MENU
>
SERVICE INFORMATION
and can be used for phone numbers less
than 13 digits in length.
7.13
RESTORE FACTORY SETTINGS
MENU > FOR SERVICEMAN > RESTORE FACTORY SETTINGS
RESTORE FACTORY SETTINGS
is used to restore all the
parameters set in the user interface to their factory
defaults.
On selecting
YES
, the process of restoring all settings to
their factory defaults begins and progress is displayed
as a percentage.
7.14
TEST RUN
7.14.1
TEST RUN Menu overview
MENU > FOR SERVICEMAN > TEST RUN
TEST RUN
is used to check that the valves, air purge function, circulation pump, space cooling mode, space heating mode
and DHW mode are all operating correctly.
Figure 3-7.35:
HOLIDAY AWAY SETTING menu
Figure 3-7.36:
SERVICE CALL menu
Figure 3-7.37:
RESTORE FACTORY SETTINGS screens
76