LP-314 Rev. 012 Rel. 003 Date 9.27.19
41
Function 52
Solar Mode
(Available on Solar Appliances Only)
SOLAR MODE
ON 52
When turned ON, this parameter enables
solar function of the control. Default:
OFF. NOTE: Turning Solar Mode “ON” will
open a number of additional parameters
to customize the solar installation. See
Solar Kit Instructions (lp-420) for details.
NOTE: Turning this Mode “ON” without a
connected Solar Kit (p/n 7100P-220) will
result in improper appliance operation.
Service calls associated with this ARE NOT
covered by warranty.
Table 17 - System Setting Program Navigation
E. Control Status Menu
The control also has the ability to review system status. To access the
status screens, press
>
. Once the first value is displayed, press
^
and
v
to scroll through additional information. At any point press
RESET
to exit the status screens.
Screen
Description
TOP TANK 160
o
F
BOT TANK 123
o
F
This screen displays the actual
temperatures measured by the top and
bottom tank sensors.
Press v once.
CH TARGET 140
o
F
CH SUPPLY 122
o
F
The current central heating temperature
set point is displayed on the top line.
NOTE:
This temperature set point may
vary from what was set in the appliance
settings if an outdoor sensor is used.
The actual temperature measured by
the hydronic heating module supply
sensor is displayed on the bottom line.
Press v once.
CH DEMAND OFF
OUTDOOR 55
o
F
The top line displays the current status
of the central heating demand. The
bottom line displays the temperature
measured by the outdoor sensor (when
used). If there is no outdoor sensor
connected to the appliance, the bottom
line will read “OFF”. If the contacts are
jumped, this line will display “ON” in
place of the temperature.
NOTE:
To ensure a properly installed
outdoor sensor, be sure that this
temperature reading is similar to the
current outdoor conditions.
Press v once.
DHW SETING 119
o
F
TANK TARGET 160
o
F
The top line displays the current
domestic hot water temperature set
point entered in the Appliance Settings.
The bottom line displays the current
tank target temperature.
NOTE:
This target tank temperature set
point will vary due to environmental
conditions and Total System Control
settings.
Press v once.
FLAME 0.0uA
FAN SPEED 3497 RPM
This screen displays appliance flame
current on the top line. The second line
displays appliance fan speed.
Press v once.
POWER ON 0h
INPUT 0kBTU
The top line indicates the amount of
hours the appliance has been powered
in its lifetime. The bottom line displays
how much energy input (in thousand
BTU) from the burner into the storage
tank.
Press v once.
DHW USE 0%
CH USE 1%
The top line of this display indicates the
percentage of energy used for domestic
hot water heating over the appliance
lifetime. The bottom line displays the
percentage of energy used for central
heating over the appliance lifetime.
Press v once.
GOOD IGNIT 0x
CH CYCLE 0x
The top line displays the number of
times the burner has been ignited over
the appliance lifetime. The bottom
line indicates the number of times the
heating module has cycled for central
heating demand.
Press v once.
FAULT HISTORY 1
07/27/2009 Mo 5:19A
This screen displays the most recent
control lockout fault. The top line
will alternate between the words
‘FAULT HISTORY’ and the fault code
encountered. The bottom line displays
the date and time the fault occurred.
Press v once.
FAULT HISTORY 2
08/28/2009 Fr 5:19A
This screen displays the second oldest
control lockout fault. The top line
will alternate between the words
‘FAULT HISTORY’ and the actual fault
encountered. The bottom line will
display the date and time that the fault
occurred.
Press v once.
FAULT HISTORY 3
08/28/2009 Fr 5:19A
This screen displays the third oldest
control lockout fault. The top line
will alternate between the words
‘FAULT HISTORY’ and the actual fault
encountered. The bottom line will
display the date and time that the fault
occurred.
Press v once.
FAULT HISTORY 4
08/28/2009 Fr 5:19A
This screen displays the fourth oldest
control lockout fault. The top line
will alternate between the words
‘FAULT HISTORY’ and the actual fault
encountered. The bottom line will
display the date and time that the fault
occurred.
Press v once.
FAULT HISTORY 5
08/28/2009 Fr 5:19A
This screen displays the fifth oldest
control lockout fault. The top line
will alternate between the words
‘FAULT HISTORY’ and the actual fault
encountered. The bottom line will
display the date and time that the fault
occurred.
Press v once.