lp-32 Rev. 003 Rel. 010 Date 2.22.19
2
The following defined terms are used throughout this manual to
bring attention to the presence of hazards of various risk levels or to
important product information.
DANGER
indicates an imminently hazardous situation which, if not
avoided, will result in serious personal injury or death.
WARNING
indicates a potentially hazardous situation which, if not
avoided, could result in personal injury or death.
CAUTION
indicates a potentially hazardous situation which, if not
avoided, may result in moderate or minor personal injury.
CAUTION used without the safety alert symbol
indicates a
potentially hazardous situation which, if not avoided, may result in
property damage.
NOTICE
is used to address practices not related to personal injury.
Foreword
This manual is intended to be used in conjunction with other literature
provided with the storage tank. This includes all related control
information. It is important that this manual, all other documents
included with this system, and additional publications be reviewed in
their entirety before beginning any work.
Installation should be made in accordance with the regulations of
the Authority Having Jurisdiction, local code authorities, and utility
companies which pertain to this type of water heating equipment.
Authority Having Jurisdiction (AHJ) – The AHJ may be a federal, state,
local government, or individual such as a fire chief, fire marshal, chief
of a fire prevention bureau, labor department or health department,
building official or electrical inspector, or others having statutory
authority. In some circumstances, the property owner or his/her agent
assumes the role, and at government installations, the commanding
officer or departmental official may be the AHJ.
NOTE:
HTP reserves the right to modify product technical specifications
and components without prior notice.
For the Installer
This storage tank must be installed by qualified and licensed personnel.
The installer should be guided by the instructions furnished with the
storage tank, and by local codes and utility company requirements.
Installations Must Comply With:
Local, state, provincial, and national codes, laws, regulations, and
ordinances.
Part 1 - General Safety Information
This storage tank is approved for indoor installations only and is
not intended for use in swimming pool applications. Clearance
to combustible materials: 0” top, bottom, sides, and back. Tank
must have room for service: 24” front and 6” sides are minimum
recommended service clearances. (A combustible door or removable
panel is acceptable front clearance.) This storage tank has been
approved for closet installation and installation on combustible
flooring. Install the storage tank in a location where temperature
and pressure relief valve discharge or a leak will not result in damage
to the surrounding area.
Installer -
Read all instructions in this manual before installing.
Perform steps in the given order.
User
- This manual is for use only by a qualified heating installer
/ service technician. Have this storage tank serviced / inspected
annually by a qualified service technician.
NOTE:
Obey all local codes. Obtain all applicable permits before
installing the storage tank.
NOTE:
Install all system components and piping in such a manner
that does not reduce the performance of any fire rated assembly.
Table of Contents
Part 1 - General Safety Information
2
A. When Servicing the Water Heating System
3
B. System Water
3
C. Freeze Protection
3
D. Water Temperature Adjustment
3
Part 2 - Prepare the Storage Tank
3
A. Locating the Storage Tank
3
B. Water Chemistry Requirements
4
Part 3 - Piping
4
A. Plumbing
4
B. Tankless Coil Connections
4
C. Hot Water Outlet
5
From the Uniform Plumbing Code 2000 - Section 510 -
Protection From Damage
1. All storage tanks installed in areas where they may be subjected
to mechanical damage shall be suitably guarded against such
damage by being installed behind adequate barriers or by being
elevated or located out of the normal path of a vehicle using any
such garage.
2. In seismic zones 3 and 4, storage tanks shall be anchored or
strapped to resist horizontal displacement due to earthquake
motion. Strapping shall be at points within the upper one-third
(1/3) and lower one-third (1/3) of its vertical dimensions. At the
lower point, a minimum distance of four (4) inches (102 mm) shall
be maintained above the controls with the strapping.
3. A storage tank supported from the ground shall rest on level
concrete or other approved base extending not less than three (3)
inches (76 mm) above the adjoining ground level.
4. When a storage tank is located in an attic, attic-ceiling assembly,
floor-ceiling assembly, or floor-subfloor assembly where damage
may result from a leaking storage tank, a watertight pan of
corrosion resistant materials shall be installed beneath the storage
tank with a minimum three-quarter (3/4) inch (20 mm) diameter
drain to an approved location.
D. Temperature and Pressure Relief Valve
6
E. Potable Expansion Tank
6
F. Scalding
6
G. Applications
7
Part 4 - Control and Wiring
7
A. Control
7
B. Wiring
7
C. Wiring Diagram
7
Part 5 - Start-Up and Operation
7
Part 6 - Maintenance and Troubleshooting
8
Ten (10) Year Limited Warranty
10
Customer Installation Record Form
12