lp-32 Rev. 003 Rel. 010 Date 2.22.19

10

Coil Booster Stainless Steel Storage Tank

Ten (10) Year Limited Warranty

For Residential and Commercial Use

HTP warrants each coil booster stainless steel storage tank to be free 

from defects in materials and workmanship according to the following 

terms, conditions, and time periods. UNLESS OTHERWISE NOTED 

THESE WARRANTIES COMMENCE ON THE DATE OF INSTALLATION. 

This limited warranty is only available to the 

original consumer 

purchaser

 (hereinafter “Owner”) of the storage tank, and is non-

transferable.

COVERAGE

A. 

This warranty covers the storage tank assembly ONLY. The storage 

tank assembly consists of a stainless steel storage tank, insulation, 

and outer jacket.

B. Should a defect or malfunction result in a leakage of water from 

the storage tank within the above-stated warranty periods due 

to defective material or workmanship, malfunction, or failure to 

comply with the above warranty, with such defect or malfunction 

having been verified by an authorized HTP representative, HTP 

will replace the defective or malfunctioning storage tank with 

a replacement of the nearest comparable model available at 

the time of replacement. The replacement storage tank will be 

warranted for the unexpired portion of the applicable warranty 

period of the original storage tank.

C. In the event of a leakage of water of a replacement storage 

tank due to defective material or workmanship, malfunction, or 

failure to comply with the above warranty, HTP reserves the right 

to refund to the Owner the published wholesale price available at 

the date of manufacture of the original storage tank.

D.  If  government  regulations,  industry  certification,  or  similar 

standards require the replacement storage tank to have features 

not found in the defective storage tank, the Owner will be charged 

the difference in price represented by those required features. If 

the Owner pays the price difference for those required features 

and/or  to  upgrade  the  size  and/or  other  features  available  on 

a new replacement storage tank, the Owner will also receive a 

complete new limited warranty for that replacement storage 

tank.

E. If at the time of a request for service the Owner cannot provide 

a copy of the original sales receipt or the warranty registration, 

the warranty period for the storage tank shall then end ten (10) 

years from the date of manufacture of the storage tank and NOT 

the date of installation of the storage tank. 

F. This warranty extends only to storage tanks utilized in heating 

applications  that  have  been  properly  installed  by  qualified 

professionals based upon the manufacturer’s installation 

instructions.

G. It is expressly agreed between HTP and the Owner that repair, 

replacement, or refund are the exclusive remedies of the Owner.

OWNER RESPONSIBILITIES

The Owner or Qualified Installer / Service Technician must:

1. Have a relief valve bearing the listing marks of the American 

Society of Mechanical Engineers (ASME) installed with the storage 

tank assembly in accordance with federal, state, and local codes.

2. Have a vacuum relief valve certified to ANSI Z21.22 - Relief 

Valves for Hot Water Supply Systems - installed with the storage 

tank assembly in accordance with federal, state, and local codes 

and in installations prone to vacuum related damages.

3. Maintain the storage tank in accordance with the maintenance 

procedure listed in the manufacturer’s provided instructions. 

Preventive  maintenance  can  help  avoid  any  unnecessary 

breakdown of the storage tank and keep it running at optimum 

efficiency.

4. Maintain all related system components in good operating 

condition. 

5. Use the storage tank in an open system, or in a closed system 

with a properly sized and installed thermal expansion tank.

6. Use the storage tank at water pressures not exceeding the 

working pressure shown on the rating plate.

7. Keep the storage tank free of damaging scale deposits.

8. Make provisions so if the storage tank or any component or 

connection thereto should leak, the resulting flow of water will 

not cause damage to the area in which it is installed.

WARRANTY EXCLUSIONS

This limited warranty will not cover:

1. Any storage tank purchased from an unauthorized dealer.

2. Any storage tank not installed by a qualified heating installer / 

service technician, or installations that do not conform to ANSI, 

CSA, and/or UL standards, as well as any applicable national or 

local building codes.

3. Service trips to teach the Owner how to install, use, maintain, 

or to bring the storage tank installation into compliance with 

local building codes and regulations.

4. The workmanship of any installer. The manufacturer disclaims 

and does not assume any liability of any nature caused by 

improper installation, repair, or maintenance.

5. Electricity or fuel costs, or increased or unrealized savings for 

same, for any reason whatsoever.

6. Any water damage arising, directly or indirectly, from any 

defect in the storage tank or component part(s) or from its use.

7. Any incidental, consequential, special, or contingent damages 

or expenses arising, directly or indirectly, from any defect in the 

storage tank or the use of the storage tank.

8. Failure to locate the storage tank in an area where leakage 

of the tank or water line connections and the relief valve will 

not result in damage to the area adjacent to the storage tank 

or lower floors of the structure, as well as failure to install the 

storage tank in or with a properly sized drain pan routed to an 

approved drainage location.

9. Any failed components of the system not manufactured by 

HTP as part of the storage tank.

10. Storage tanks repaired or altered without the prior written 

approval of HTP.

11. Damages, malfunctions, or failures resulting from improper 

installation, or failure to install the storage tank in accordance 

with applicable building codes/ordinances or good plumbing 

and electrical trade practices; or failure to operate and maintain 

the storage tank in accordance with the manufacturer’s provided 

instructions. 

12. Damages, malfunctions, or failures resulting from failure to 

operate the storage tank at pressures not exceeding the working 

pressure shown on the rating label.

13. Failure to operate the storage tank in an open system, or 

in a closed system with a properly sized and installed thermal 

expansion tank.

14. Failure or performance problems caused by improper sizing 

of the storage tank, expansion device, or piping.

15. Damages, malfunctions, or failures resulting from vacuum 

conditions.

16. Damages, malfunctions, or failures caused by operating the 

storage tank with modified, altered, or unapproved components, 

or any component / attachment not supplied by HTP.

17. Damages, malfunctions, or failures caused by abuse, accident, 

fire, flood, freeze, lightning, electrochemical reaction, acts of God 

and the like.

18. Tank failures (leaks) caused by operating the storage tank in 

a corrosive or contaminated atmosphere. 

19. Failure of the tank due to the accumulation of solid materials 

or lime deposits.

20.  Any damage or failure resulting from improper water 

Содержание Superstor Ultra SSU CB Series

Страница 1: ...could result in substantial property damage severe personal injury or death The manufacturer reserves the right to make product changes or updates without notice and will not be held liable for typog...

Страница 2: ...bustibledoororremovable panel is acceptable front clearance This storage tank has been approved for closet installation and installation on combustible flooring Install the storage tank in a location...

Страница 3: ...ping where it will not be exposed to freezing temperatures All piping should be insulated Additionally place the storage tank so that the drain controls and inlets outlets are easily accessible NOTE T...

Страница 4: ...up to the installer to ensure the water does not contain corrosive chemicals or elements that can damage the heat exchanger Potable water is defined as drinkable water supplied from utility or well w...

Страница 5: ...6 above the structural floor and not contact any live electrical parts In the bottom of the tee branch vertically down install a 3 4 NPT x 3 4 minimum tube adapter Then install two 3 4 minimum sweat...

Страница 6: ...L INJURY OR DEATH E Potable Expansion Tank A potable hot water expansion tank may be required to offset heated water expansion If there is a back flow preventer or any other type of no return or check...

Страница 7: ...system by opening a hot water outlet at a fixture in a kitchen or bathroom When water flows freely from the outlet the system is purged Part 5 Start Up and Operation When filling the storage tank open...

Страница 8: ...e operating range Temperatures Verify safe settings on Mixing Valve if installed in system Electrical Smoke and CO Detectors Verify devices are installed and working properly Change batteries if nec e...

Страница 9: ...eck Not enough space heat Boiler sized too small Consult chart Slow recovery Circulator head capacity too low T P Valve Discharges Hot Tubs Spas Multiple Showers High Demand Problem Possible Solution...