lp-673 Rev. 000 Rel. 001 Date 8.30.18
14
Description
Diameter
A
Air Intake
-
B
Exhaust Vent
-
C
DHW Outlet Adapter
1 1/4” NPT
D
DHW Inlet Adapter
1 1/4” NPT
E
Gas Inlet Adapter
3/4” NPT
F
Condensate Adapter
1/2” NPT (3/4” PVC Socket on Floor Models)
Table 13 - Adapter Specifications
Figure 5 - Wall Model Dimensions
Figure 6 - Floor Model Dimensions