6 Operation and regulation
86
HSD S.p.A. © - 0106h03a.fm100713
6.9.4
Technical characteristics of the Bauer sine
encoder
Trend of signal A over time:
CHARACTERISTICS
VALUE
Rated power supply "U"
5V DC +/- 5%
Operating temperature
-30° C ÷ 85° C (-22° F ÷ 185° F)
Max. operating altitude
2000m (6500ft)
Signal input
128 pulses per ro zero notch
100 pulses per ro zero notch
A/B signal output
500 mV peak-to-peak with average value “U ref.”=U/2
1V peak-to-peak as difference of signals with
average value “U ref.” (see figures below)
A/B signal phase displacement
90° (a quarter period)
Z signal output
500 mV peak compared with idle value
U ref. ±80mV
1V peak as difference of signals with idle value U ref.-
160mV= 2.34V (see figures below)
A voltage level higher than the one specified (5V ±5%) may damage the encoder
reader.
A+
A–
A+
DIFF
= (A+) – (A–)
360° electrical de-
Содержание ES327
Страница 2: ......
Страница 4: ...Information about the publication 4 HSD S p A H5801H0084 fm100713 ...
Страница 21: ...2 Technical Specifications HSD S p A 0102h00a fm100713 21 2 4 ES331 Main parts 3 5 2 6 4 12 7 9 10 8 11 1 ...
Страница 25: ...2 Technical Specifications HSD S p A 0102h00a fm100713 25 2 6 ES370 Main parts 7 6 8 1 2 4 3 10 5 11 12 9 ...
Страница 46: ...3 Transport packing unpacking storage 46 HSD S p A 0103h03a fm100713 ...
Страница 59: ...4 Installation and commissioning HSD S p A 0104h03a fm100713 59 ES331 ES332 1 2 4 3 1 2 4 3 ...
Страница 66: ...4 Installation and commissioning 66 HSD S p A 0104h03a fm100713 ...
Страница 112: ...9 Disposal of the product 112 HSD S p A 0109h03a fm100713 ...
Страница 116: ...10 Troubleshooting 116 HSD S p A 0110h00a fm100713 ...
Страница 121: ......