8 Replacing components
104
HSD S.p.A. © - 0108h02a.fm100713
8.4.4
Replacement and adjustment of the sensor unit
Procedure not valid for model “liquid” ES330
which locks the sensor unit to be replaced;
2. remove the worn sensor unit from its seat;
3. Disconnect the sensor electronically or (if present) its electronic connector
;
4. electronically connect the new sensor unit;
5. verify the functionality of the new sensor by placing it in contact with a metal object;
6. insert the new sensor unit in the empty seat;
7. rescrew the screw
without tightening it completely, so that the sensor unit can rotate;
8. adjust the sensor unit, so as to obtain the outputs required in the paragraphs immediately
below;
tighten the screw
locking the sensor unit, so as to maintain the performed calibration.
For the replacement and adjustment of the sensors illustrated in this and subsequent
paragraphs, refer to figures
and
of the previous paragraph.
Содержание ES327
Страница 2: ......
Страница 4: ...Information about the publication 4 HSD S p A H5801H0084 fm100713 ...
Страница 21: ...2 Technical Specifications HSD S p A 0102h00a fm100713 21 2 4 ES331 Main parts 3 5 2 6 4 12 7 9 10 8 11 1 ...
Страница 25: ...2 Technical Specifications HSD S p A 0102h00a fm100713 25 2 6 ES370 Main parts 7 6 8 1 2 4 3 10 5 11 12 9 ...
Страница 46: ...3 Transport packing unpacking storage 46 HSD S p A 0103h03a fm100713 ...
Страница 59: ...4 Installation and commissioning HSD S p A 0104h03a fm100713 59 ES331 ES332 1 2 4 3 1 2 4 3 ...
Страница 66: ...4 Installation and commissioning 66 HSD S p A 0104h03a fm100713 ...
Страница 112: ...9 Disposal of the product 112 HSD S p A 0109h03a fm100713 ...
Страница 116: ...10 Troubleshooting 116 HSD S p A 0110h00a fm100713 ...
Страница 121: ......