Assembly and alignment
12
2018-06-19
FM 239 MuW Beta-Typ-Z Rev.01
distributed by
6
Assembly and alignment
The linear unit can be mounted as follows:
With mounting brackets
With screws in the sliding blocks
With screws in the factory-fitted threaded rails
Mount the linear unit only on a flat surface. Standard parallelism
<0.2 mm/1000 mm.
Mounting the linear unit using the threaded rails is recommended
for the following situations:
for highly dynamic applications
where the linear unit is attached at only 2 fixing points
6.1
Assembling the linear unit with mounting brackets
Figure 2: Mounting brackets (1)
The recommended maximum distance between the mounting
brackets is 700 mm.
Proceed as follows
1.
Loosely fit the mounting brackets (1) into position (Figure 2).
2.
Align the linear unit axially.
3.
Screw the mounting brackets (1) into place
(for tightening torques refer to Section 3).