- 48 -
„I
Start
“
If I
Target
is activated I
start
appears. This value defines the point at which
the stroke measurement for the setting step should be started.
„I
limit
“
I
limit
describes the maximum current which the tool may reach in this
step. If this value is reached the tool will stop and display the NOK error
message.
„I
limit"
“
I
limit"
describes the minimum current which the tool may not fall below
in this step. If this value is not reached the tool will stop and display the
NOK error message. I
limit"
will be actively monitored after reaching l
start
.
Time
„T
Target
“
T
Target
describes the time which the tool should run in this step. If this
value is reached the tool will switch to the next step.
„T
limit
“
T
limit
describes the maximum time which the tool may be in this step.
If this value is reached the tool will stop and display the NOK error
message.
Switch
„Pressure trigger“
If the pressure switch function is activated during the step the pressure
switch must be activated. Default: deactivated
„Final switch“
The limit switch function must be activated in the last programmed
step so that the tool can not move on the block.
DANGER
Risk of injury due to incorrect settings
Incorrect settings can lead to injuries or damages
• Settings may only be completed by experienced users