Im Martelacker 12 – D-79588 Efringen-Kirchen – Phone 0 76 28 - 91 11- 0 – Fax 0 76 28 - 91 11-90
E-Mail: [email protected] – Web: www.hs-technik.com
- 18 -
battery defective
voltage limit
temperature
temperature contact missing
charging
battery full
ON
OFF
battery defective
voltage limit
temperature
temperature contact missing
charging
battery full
ON
OFF
battery defective
voltage limit
temperature
temperature contact missing
charging
battery full
ON
OFF
battery defective
voltage limit
temperature
temperature contact missing
charging
battery full
ON
OFF
3.2.0. EXPLANATION OF THE LED SIGNALS / FUNCTIONS
When the charging station is not in use, it switches to
sleep mode. In order to be able to charge a battery,
the station must be activated by pressing the "wake up"
button. This is located on the lower left of the front side.
If the button is lit green, the charging station is switched on
and batteries can be charged. If the button is pressed for longer than 10
seconds, the charging station switches to sleep mode.
Continuously lit red:
Battery is charging
Continuously lit green:
Battery is fully charged
Blinking blue:
Temperature is too high or too low to charge.
If the temperature of the battery is below
10° C, the LED will blink blue and the
charging station will only charge the
battery with 500 mA up to a temperature of 10° C has been reached. From
then on, the station will charge the battery normally. The same applies
when the temperature of the battery exceeds 55° C; the battery will also
be charged with 500 mA until the temperature of the battery drops below
55° C.
Blinking red/blue:
The charging station cannot
find a temperature contact.
In most cases, the battery contact
is defective or damaged.
Blinking red:
The battery is defective. The charging
station cannot find a measurable
voltage.
Blinking yellow:
The battery voltage is too high or too
low for the battery type. This battery
cannot be charged.