Im Martelacker 12 – D-79588 Efringen-Kirchen – Phone 0 76 28 - 91 11- 0 – Fax 0 76 28 - 91 11-90
E-Mail: [email protected] – Web: www.hs-technik.com
- 17 -
When replacing batteries, make sure the new battery is not inserted until the
LEDs have gone out (red or green).
If a battery is replaced very quickly, the electronics may retain the status of
the previous battery pack.
3.2.0. CHARGING PROCESS
Via an initialization routine, the voltage, temperature, short circuits and
reverse polarity of the inserted battery are checked.
Prior to starting the charging process, the temperature contacts (NTC
contact, etc.) are checked. If the temperature contacts are OK, the battery
will be charged.
If the battery is too hot, it can stay in the charging station, and when it
has cooled down, it will automatically charge.
If the red LED lights up, the charging process will start using the
special HST frequency modulation impulse process
®
and charge the
battery based on how depleted the battery is.
During the charging process, the voltage and temperature of the cells and
the remaining charging time are continuously monitored.
Taking all of the parameters into account, the charging current and
remaining charging time varies on a case-by-case basis. The installed fans
switch on automatically, as needed during each charging process.
Every charging process is recorded on a memory chip for subsequent
evaluation.