O
PERATING
Y
OUR
B
OILER (continued)
PAGE 50
_____________________________________________________________________________________________________________________________________________________________________________________
AQUASTAT CONTROLSETTINGS DURING SUMMER (NON-HEATING SEASON)
The aquastat settings below will give good results,
when the Tarm EXCEL is installed with a
heat storage tank system,
for heating domestic hot water (DHW) during the summer, non-
heating season.
Honeywell L8124C (on boiler)
Scale
Setting
Function
LO
210
°
F
Boiler Overheat... starts Circulator C-3 and overrides room
thermostat for “dump zone” to dissipate excess heat
HI
180
°
F
Boiler Operating temperature for all Modes
DIFF
10
°
F
Operating Differential
Honeywell L6081A (on boiler)
Scale
Setting
Function
LO
165
°
F
Temperature setting at which Circulator C-3 starts operating
HI
200
°
F
Backup high temperature limit for all modes
DIFF
10
°
F
Operating Differential
Honeywell L8151A (on optional heat storage tank)
Scale
Setting
Function
LO
120
°
F
Temperature setting at which oil or gas burner starts again after
heat storage tank has been heated up to “HI” setting on L8151A
and then cooled down.
HI
160
°
F
Heat Storage Tank Operating temperature when being heated by
oil or gas burner when the boiler is in either the “BACK-UP ONLY”
or the “AUTO BACK-UP” operating mode.
DIFF
10
°
F
Operating Differential
50
Содержание 2000
Страница 1: ......
Страница 4: ......
Страница 8: ... Intentionally left blank PAGE 4 4 ...
Страница 13: ...FEATURES AND SPECIFICATIONS PAGE 9 9 ...
Страница 28: ...FIELD WIRING DIAGRAMS PAGE 24 ...
Страница 29: ...24 WIRING SCHEMATIC FOR CONTROLS PAGE 25 ...
Страница 30: ...This is an insert page 25 ...
Страница 63: ...TARM EXCEL CAUTION LABEL PAGE 58 58 ...
Страница 65: ...BOILER Parts List PAGE 60 60 ...
Страница 66: ...BOILER Parts List PAGE 61 61 ...