General Information
7
HQUA
Section 3 Maintenance
Prerequisites:
•
Always Disconnect power supply before performing any work on UV water sterilizer.
•
Always shut-off water flow and release water pressure before servicing.
• Regularly inspect power indicators on the ballast :the green one represent the ballast and red
one represent the UV lamp. Both on means our product is working on a good condition.If the
green one is off and the red one is on,it’s still working!But we suggest you check the UV lamp
situation with protection of your eyes and skin.
•
Replace the UV lamp annually (or biennially if seasonal home use) to ensure maximum disinfection.
3.1 Replace the UV lamp
Replcing an UV lamp is quite easy and take a little time with it.One UV lamp’s lifetime is nearby
9000 hours, so it should be replaced annually to keep its enough disinfection for 12GPM water flow.
Procedures: