Troubleshooting
10
HQUA
Section 4 Troubleshooting
Symptom
Possible Cause
Solution
Green Light Off
GFCI and/or breaker tripped
Reset GFCI and/or breaker
Ballast damaged
Replace ballast and use a TVSS
Red Light Off
Connection problem
Power off&wait 15 minutes,adjust
the connection between UV lamp
and the ballast.Then try it again
UV lamp damaged or died
Replace it with a new one
Leak at inlet or outlet
Threaded pipe fittings are leaking
Clean threads, reseal with Teflon
tape and retighten
System is operating but
water
tests
reveal
bacterial contamination
Equipment downstream of UV system
is acting as a breeding ground for
pathogens
Ensure UV is the last piece of
treatment equipment
Recontamination from pipe dead-ends
Remove any pipe dead-ends and
flush with chlorine
Section 5 After-Sales Service
Should you need any support, or have questions about your system, please contact
our Technical Support team at [email protected] and we will be happy to assist you.
We sincerely hope you enjoy the benefits of clean, safe drinking water after the
installation of your HQUA disinfection system.