Discharging a Lithium battery
LiPo DISCGARGE
1.0A
11.1V(3S)
DEC INC
DEC INC
START
ENTER
BATT
STOP
The value of the discharge current on the left of the screen can not
exceed 1C, and the value on the right can not be under the voltage
recommended by the manufacturer to avoid deep discharging. Press
START/ENTER for more than 3 seconds to start discharging.
This screen shows the real time status of the discharging, you can press
BATT.TYPE/STOP key to stop discharging at any time.
LP3S
0.4A 12.59V
DSC
22:43
00682
Number
of cells
Elaspsed
Time
Battery
Voltage
The processor monitors the voltage of each cell during the “STORAGE” and “DISCHARGING”
process. If the voltage of any cell is abnormal, the Reactor 500 will show an error message and
stop the current process. By pressing the “INC” key a report can be seen which will let you know
which cells are reading abnormally.
Voltage balancing and monitoring during the discharge process
If this screen shows, the processor has detected that the voltage of one
cell is too low.
CELL LOW VOL
This screen can show the listed voltage of each cell. In this case the
4th cell is damaged. The voltage levels can be seen if the charger auto
detects a problem.
4.14
4.16
4.09
2.18
0.00
0.00
BATTERY VOL ERR
INC
Discharge
Current
Discharged
Capacity
>3 Seconds