14
Initial Parameter Setup (User Setup)
Temp Cut-Off
With use of the optional temperature probe you can set the
temperature cut off to ON or OFF. If you set to ON, you can set the
maximum temperature at which the charger should allow the battery
to reach during charge. Once a battery reaches this limit, the charge
process will be stopped to protect the battery.
Waste Time
10Min
CHG>DCHG
The battery becomes warm after process cycles of charge/discharge.
This program will insert a time delay after each charge/discharge
process to allow the battery to cool down before beginning the next
cycle. The value ranges from 0 to 60 minutes.
DEC INC
DEC INC
ON
80°C
DEC
INC
DEC
INC
This shows the trigger voltage for the automatic charge termination of
NiMH and NiCd batteries. The effective values range from 5 to 20mV
per cell. If the trigger voltage is set higher, there is a danger of over
charging the battery. If the value is set lower then a premature
termination is likely. Please refer to the technical specifications of your
battery. (Default settings: NiCd: 12mV, NiMH: 7mv)
NiMH Sensitivity
D. Peak
Default
NiCd Sensitivity
D. Peak
Default
DEC INC
DEC INC
DEC
INC
DEC
INC
DEC INC
DEC INC
Содержание reactor 500