Item
Description
Status
3
NIC status LED
Solid green = Link to network
Flashing green (1 flash per second) = Network active
Off = No network activity
4
UID button/LED
Solid blue = Activated
Flashing blue:
• 1 flash per second = Remote management or
firmware upgrade in progress
• 4 flashes per second = iLO manual reboot
sequence initiated
• 8 flashes per second = iLO manual reboot
sequence in progress
Off = Deactivated
If the system power LED is off, verify the following conditions:
• Facility power is present.
• The power supply is installed and is working correctly.
• The power cord is attached and is connected to a power source.
• The front I/O cable is connected.
If the health LED indicates a degraded or critical state, review the system Integrated Management Log (IML) or use
HPE iLO to review the system health status.
If all LEDs described in this table flash simultaneously, a power fault has occurred. For more information,
see "
".
UID button functionality
The UID button can be used to display the Server Health Summary when the server will not power on.
For more information, see the iLO user guide on the Hewlett Packard Enterprise website (
Front panel LED power fault codes
The following table provides a list of power fault codes, and the subsystems that are affected. Not all
power faults are used by all servers.
Subsystem
LED behavior
System board
1 flash
Processor
2 flashes
Memory
3 flashes
Riser board PCIe slots
4 flashes
FlexibleLOM
5 flashes
Table Continued
100
Component identification
Содержание ProLiant DL325
Страница 13: ...Customer self repair 13 ...
Страница 14: ...14 Customer self repair ...
Страница 15: ...Customer self repair 15 ...
Страница 16: ...16 Customer self repair ...
Страница 51: ... Slot 2 Slot 3 To replace the component reverse the removal procedure Removal and replacement procedures 51 ...
Страница 57: ... SFF a Remove the optical drive cage b Remove the optical drive Removal and replacement procedures 57 ...
Страница 62: ...10 Remove the iLO service port assembly 11 Remove the front I O module 62 Removal and replacement procedures ...
Страница 116: ... 4LFF drive connected to type a controller 4LFF drive connected to type p controller Slot 1 116 Cabling ...
Страница 117: ... Slot 2 Slot 3 Cabling 117 ...
Страница 120: ... Slot 2 Slot 3 120 Cabling ...
Страница 126: ...Cable routing Power supply Non hot plug power supply Power distribution board PDB to system board 126 Cabling ...
Страница 128: ...Item Description Orange Front I O cable Blue Ambient temperature sensor cable Cable routing USB 3 0 LFF SFF 128 Cabling ...
Страница 129: ...Cable routing Serial port Cabling 129 ...
Страница 130: ...Cable routing Chassis Intrusion Detection switch Cable routing M 2 SSD Slot 1 Slot 2 130 Cabling ...
Страница 132: ... Slot 2 Slot 3 132 Cabling ...
Страница 133: ...Cable routing Energy pack Cabling 133 ...