VIO Enclosure and Disk Storage Considerations
These considerations apply to an NS2100 system:
•
Only configurations with two VIO enclosures are supported.
•
The group number for the VIO enclosures is 100.
•
Up to eight SAS disk enclosures can be connected to the HBA Fibre Channel interfaces on
a Storage CLIM that connects to the VIO enclosure in the NS2100 system.
•
Two Ethernet connections, one in each VIO enclosure module, that connect to the
maintenance entity (ME) are necessary to enable the OSM Service Connection and OSM
Notification Director.
Ethernet to Networks
Depending on your configuration, Gigabit Ethernet connectivity is provided by the Ethernet
interfaces in one of these CLIMs or the Ethernet ports on the VIO enclosure:
•
“IP CLIM Ethernet Interfaces” (page 84)
•
“Telco CLIM Ethernet Interfaces” (page 86)
•
“VIO Enclosure Ethernet Ports” (page 87)
The IP CLIM, Telco CLIM, or the Ethernet ports on a VIO enclosure provide Ethernet connectivity
between NS2100 commercial systems and Ethernet LANs. The Ethernet port is an end node on
the ServerNet and uses either fiber-optic or copper cable for connectivity to user application
LANs, as well as for the dedicated service LAN.
These are the front views of each CLIM model. For an illustration of the back views, refer to each
supported CLIM Ethernet Interface.
IP CLIM Ethernet Interfaces
The DL380 G6 and DL380p Gen8 IP CLIM each have two types of Ethernet configurations: IP
CLIM option 1 and IP CLIM option 2.
•
IP CLIM option 1 provides five Ethernet copper ports.
•
IP CLIM option 2 provides three Ethernet copper ports and two Ethernet optical ports.
NOTE:
The Telco CLIM Ethernet interfaces are identical to an IP CLIM with Configuration A.
For more information, see
“Telco CLIM Ethernet Interfaces” (page 86)
84
System Configuration Guidelines for NS2100 Systems
Содержание Integrity NonStop NS2100
Страница 48: ...Figure 11 Modular PDU Connections Without UPS 48 System Installation Specifications for NS2100 Systems ...
Страница 49: ...Figure 12 Modular PDU Connections With Single Phase UPS Power Distribution for NS2100 Systems 49 ...
Страница 52: ...Figure 14 Example of Bottom AC Power Feed Without UPS 52 System Installation Specifications for NS2100 Systems ...
Страница 53: ...Figure 15 Example of Top AC Power Feed Without UPS Power Distribution for NS2100 Systems 53 ...
Страница 55: ...Figure 17 Example of Bottom AC Power Feed With Single Phase UPS Power Distribution for NS2100 Systems 55 ...
Страница 91: ...Figure 30 Example 36U Configuration Without UPS and ERM Typical NS2100 Configurations 91 ...
Страница 107: ...System Down OSM Low Level Link 107 ...