4. Enter the
TFTP Retry Count
value.
5. Click
Save
to save the changes.
12.3 Firmware Information
This page is used to configure the Firmware Information settings.
To open System Administrator page, click
Maintenance > Firmware Information
from the menu bar.
A sample screenshot of Firmware Information page is shown below.
The various fields of Firmware Information page are given below.
Active Firmware
Build Date
: Describes the Build Date of the active BMC image.
Build Time
: Describes the Build Time of the active BMC image.
Firmware version
: Describes the Firmware version of the active BMC image.
12.4 Firmware Update
This wizard takes you through the process of firmware upgradation. Areset of the box will automatically
follow if the upgrade is completed or cancelled. An option to Preserve All Configuration is available.
Enable it, if you
wish
to preserve configured settings through the upgrade.
Warning: Please note that after entering update mode widgets, other web pages and services will
not work. All open widgets will be closed automatically. If upgrade process is cancelled in the
middle of the wizard, the device will be reset.
Note: The firmware upgrade process is a crucial operation. Make sure that the chances of a power
or connectivity loss are minimal when performing this operation.
Once you enter into Update Mode and choose to cancel the firmware flash operation, the BMC must
be reset. This means that you must close the Internet browser and log back onto the BMC before
you can perform any other types of operations.