The Sensor Readings page contains the following information:
In
WKH
Sensor Reading page,
O
ive readings
GLVSOD\
for all the available sensors with details
VXFKDV
Sensor Name,
Status, Current Reading and Behavior
6.1 Sensor detail
Select a particular Sensor from the Critical Sensor or Normal Sensor lists. The Sensor Information as Live Widget
and Thresholds for the selected sensor will be displayed as shown
LQWKHIROORZLQJVFUHHQVKRW
.
For Illustrative Purpose, a sample screenshot of Sensor detail page with Change Thresholds option is shown and
explained
LQWKHIROORZLQJVFUHHQVKRW
.
Note:
Widgets provide real time information about a particular sensor. User
V
can track a sensor's behavior over a
specific amount of time at specific intervals. The result will be displayed as a line graph in the widget. The session
will not expire, until the widgets
UHFHLYHV
a live data of the last widget that is kept opened.
For the selected sensor, this widget gives a dynamic representation of the readings for the sensor.
There are six types of thresholds:
· Lower Non-Recoverable (LNR)
· Lower Critical (LC)
· Lower Non-Critical (LNC)
· Upper Non-Recoverable (UNR)
· Upper Critical (UC)
· Upper Non-Critical (UNC)